RTS CMO Remote

Before programming the motor make sure the limits are depressed on the RTS CMO motor.

Step 1

Check the directions by pressing the Up or Down buttons (the motor will work in momentary function). To change the direction press and hold the Stop button until the motor jogs.

Step 2

Bring the motor to your desired upper limit. Now press both the Stop and Down buttons until the motor moves, then release. Stop the motor where the lower limit should be set, you can adjust by pressing the Up or Down buttons.

Step 3

Press and hold the Stop and Up buttons until the motor moves up, the motor will stop at the original upper limit point, adjust if necessary.

Step 4

Press and hold the Stop button until the motor jogs to confirm the limit setting.

Step 5

Press and hold the Program button on the back of the transmitter until the motor jogs. It will now operate in a maintained function. Double check limits as a precaution.